Any local wastewater treatment equipment has to be serviced from time to time. In most cases, the general rules for preventive maintenance and VOC cleaning are applied. And most of them can be done independently.
The only difficult moment is the maintenance of the septic tank in the winter in the cold. After all, not every model of autonomous sewage is generally adapted to work in the winter.
In this article we will tell you how to maintain a septic tank in the winter season, as well as provide valuable recommendations on the prevention of siltation of treatment facilities.
Reasons and terms of service of septic tanks
All local treatment facilities are subject to regular cleaning and inspection. They can be aerobic or anaerobic, but they still need to be checked and maintained. The timing of maintenance and pumping of silt deposits for each septic tank model is set by the manufacturer. But much here depends on the capacity of the storage capacity and the volumes of effluents entering it.
At a minimum, it is recommended that the performance check of all internal systems in VOCs be carried out in spring and autumn. The accumulated sludge should also be pumped out twice a year. But if the intensity of use of the septic tank is high, then it will be necessary to call the scavengers more often.
Image Gallery
Photo from
Most septic tanks and sewage plants of factory production are designed for year-round use. True, work without additional thermal insulation is possible only up to -10º. Cleaning stations are equipped with insulated lids that protect against freezing
As in any other period, the condition of the sewer station must be studied at least once a week, the condition of the septic installation - at least once a month
At each inspection of the sewer station, it is necessary to examine the condition of the aerators and airlifts, the performance of the compressors and biological filling
Inspection is subject not only to a sewage treatment plant (station or septic tank), but also to the soil post-treatment systems that work with it: an absorption well, a filtration field or an infiltrator
If excessive siltation of the treatment plant is detected, water samples are taken before washing. They will help to find the reasons for the intensive formation of sludge and develop measures to prevent this phenomenon.
In regions with a characteristic average temperature in winter below -10º, a septic tank and a sewer station must be insulated. The depth of the thermal insulation shell should be 15 cm greater than the level of seasonal freezing
When installing an autonomous sewage system in the northern regions of the country, methods of thermal insulation of a treatment plant should be developed at the design stage, implemented at the stage of assembly of the sewage system and installation of the external part. You can’t dig a septic tank in cold weather! Ideally, in a pit it is better to arrange a wooden box for a station or septic tank, and put thermal insulation between the walls
If measures for thermal insulation of the treatment plant have not been taken, it needs to be frozen: pump out the wastewater by 2/3, remove the cells with aerobes, compressors and transfer them to a heated place
Sewer station operation in winter
Regular inspection and inspection of technical condition
Checking the operation of station compressors
Inspection of all components of the sewer system
Laboratory Sampling
Thermal insulation of sewer station
Installation of the station in a box with thermal insulation
Sewage station pumping
According to manufacturers, aerobic autonomous sewers require less frequent pumping of silt sediment than anaerobic counterparts. However, the volume of effluents and their composition play an important role here. Residents of private houses often wash not only organic food debris, but also solid, non-degradable materials and objects together with water in sinks and toilets.
Another problem is the discharge of chlorine-containing and highly acidic liquids into the septic tank. They destroy the microflora of activated sludge. The number of microorganisms decreases sharply, the organic matter in the effluent is not processed, but only accumulates in the metatank. In this case, the filling of VOCs is much faster, so cleaning has to be done more often.
The volume of the septic tank should be selected in accordance with the daily norm of water consumption per person. It makes no sense to buy too big or too small. Actual capacity should be 1/3 more than the water consumption of all family members plus volley discharge
Maintenance regulations for household VOCs in winter
Each septic tank is accompanied by a passport with detailed rules for operation and preventive maintenance. Only compliance with these standards guarantees the correct operation of the entire treatment system.
On average, a routine inspection and cleaning of the septic tank from sludge should be done 2-3 times a year, one of which is necessary in the winter
Maintenance of an autonomous sewage system in winter is associated with a number of problems. And the main one is the low outdoor temperatures. The septic tank after installation is completely buried in the ground, only the lid remains on top.
Usually it is additionally insulated with thermal insulation materials and covered with a layer of soil up to a meter thick.
If the septic tank is installed exactly according to the rules below the level of soil freezing, then inside it throughout the year the temperature does not drop to minus marks. Earth at depths below the bottom of the septic tank itself freezes only in very cold regions and in severe frosts.
Plus, bacteria that process organics, as a result of their life, create a considerable amount of heat.
The sewer outlet from the house, the pipe to the septic tank and most of this tank should be below the gas treatment unit and be insulated - the only way they will not freeze in the cold
Many septic tank models are designed for operation at outdoor temperatures up to minus 10 ° С. In such conditions, they work without problems in the winter and are subject to maintenance. With more severe frosts, all preventive measures and cleaning should be postponed for several weeks until warming.
Opening the sump hatch in severe frost will lead to a sharp cooling and freezing of water inside, which will inevitably put the septic tank out of order.
Rules and maintenance process
The main measure during the maintenance of the septic tank is the removal of excess sediment. For autonomous sewage to work optimally and efficiently, the volume of sludge in it should be at the level of 15-30% of the metatank cubic capacity.
If there will be less of it, then there will be too few microorganisms for the complete processing of effluents. And if there is more, then there will be too little space for new waters.
In order to determine the amount of accumulated sludge by eye, it is necessary to stop the septic tank and scoop up a liquid from it with a two-liter can. As sediment settles in this water tank, sediment precipitates at its bottom. If in the end it turned out to be more than a third of the can’s capacity, then it’s time to clean the metatanks.
With an excessive content of activated sludge, it begins to thicken, which gradually leads to a decrease in the efficiency of VOCs. Excess sediment must be removed. And it doesn’t matter here - summer at this moment is outside or winter. If a septic tank is needed in working condition, then it will have to be cleaned regularly.
Pumping and cleaning of the autonomous sewage system can be done by yourself, but it is better to delegate this dirty work to professional dumpers
Excess waste sludge is removed using a fecal pump. You can do this yourself by pumping the processed sludge from the septic sump into the compost pit for fertilizers, or by shifting this procedure onto the shoulders of the sewage system.
Undecomposed organic matter and inorganic sediment must also be removed from the septic tank. In addition, during its maintenance with clean water, internal pumps, nozzles and elements of the aeration installation are cleaned.
A full range of VOC cleaning activities includes:
- visual determination of the degree of contamination of the station;
- washing the chambers and equipment of the septic tank from accumulated sludge;
- purification of clean water filters and compressor technology;
- extraction from the inside of all solid and not having time to decompose remains;
- flushing with pipe and hoses inside the unit;
- disinfection of a treatment plant;
- replacement of membranes in the compressor;
- the addition of bioactivators (with too few microorganisms in the metatank).
At the end of cleaning, the entire complex of equipment is checked for serviceability and correct operation. And then the septic tank is again filled with water for 80–85% of the total volume.
The manhole cover and its fastenings are also inspected. If there is a breakdown, then they will have to be fixed. It does not hurt to check the correctness of the automation settings, with which all processes in the septic tank are controlled.
Pumping wastewater between the sections of the sump, aeration and mixing of the water should be carried out according to the technology developed by the VOC manufacturer and the program.
Image Gallery
Photo from
Snow clearing over a sewage treatment plant
Inspection of the status of the treatment plant
Freely opening hatch of each camera
Water below the freezing horizon
Features of the septic tank in cold weather
If the equipment is chosen correctly and the sewage system is designed according to the rules, then the septic tank will work properly even at low street temperatures. It just cannot be opened in severe frosts so that the water inside does not freeze from the cold.
Absorbing organic matter in drains, microorganisms generate heat. If the tank is closed, then freezing and failure does not threaten it by definition. Even with simple VOCs, the water inside does not cool below + 3-5 ° C. And when the effluent arrives, the temperature rises altogether to 10–30 ° С.
Under such conditions, the bacteria in activated sludge feel excellent and continue to process the organic matter received in the metatank.
A properly mounted septic tank functions normally in winter. It is often even installed and put into operation in the winter months, and difficulties can arise only with digging frozen ground
Builders are ready to put septic tanks on personal plots all year round. Winter does not interfere with the installation work. The downside of the winter installation is only one - the higher complexity of digging a pit in the ground under the station for bacterial wastewater treatment from a private house.
Among the advantages of installing a septic tank in the cold are:
- The presence of a large number of free teams of installers.
- Reduced groundwater level.
- The ability to install VOCs in a pit dug in floating or crumbling soil.
The technology of winter installation of a septic tank is no different from summer. And this applies not only to installation, but also to commissioning and subsequent operation. In winter, the septic tank operates in normal operating mode.
Only in the northern regions it and the sewer pipe from the house will need to be additionally insulated, and how to do this, read in this material. And with especially severe frosts, you should forget about the opening of technological hatches, so that the cold could not penetrate into the sump.
If drains ceased to flow into the septic tank in winter, then the first thing to do is to check the freezing sewer pipe for freezing
The main weak point in the septic tank in winter is the sewer pipe from it to the house. It is she who most often freezes in the cold. And then the drains simply can not get from the cottage to the treatment station. To defrost the pipeline, pour hot water into it.
But a similar method can only help with small ice caps. In other cases, it is better to entrust an experienced plumber to restore the septic tank to working.
Prevention of clogging and siltation
In order to avoid problems with autonomous sewage in winter, the following simple rules should be observed:
- Do not rinse plastic bags, synthetic rags, or other inorganic materials into the sewers.
- It is advisable to install filters for rough mechanical treatment of effluents before they enter the septic tank.
- It is necessary to minimize the ingress of liquids containing chlorine, acid and alkali, as well as medicines, bleaches and oil products into the drain.
On the one hand, solid non-biodegradable waste can clog the pipes and systems of the septic tank. On the other hand, there are many liquids that, if spilled into VOCs, will lead to the death of microflora in it. In both cases, the autonomous sewer system will cease to fulfill its functions.
If the house is in a region with low average daily air temperatures in winter, then the septic tank is subject to mandatory insulation
The problems of a septic tank can be associated not only with the siltation or dying of a colony of bacteria, but also with the narrowing of the pipe drains leading to it due to clogging with garbage. Here, only cleaning the pipeline mechanically or hydrodynamically will help.
Another problem is power outages in aerobic VOCs. Without power, the aerator and water pumps do not work. And this is a direct way to sedimentation and stagnation of silt.
If power was not supplied to the treatment station with aerobes for several hours, then after the appearance of electricity, it is worth checking how it works properly after such a downtime. An unscheduled check in this case will definitely not be superfluous.
What methods can clean the sump?
For pumping sludge from a septic tank, a fecal pump is needed. You will also need a container for carrying sludge to a compost pit or for disposal. Doing VOCs with your own hands is a thankless task. It is often better to call a cesspool machine. A call costs money, but you don’t have to bother with dirt and sewage.
Septic tank sludge is a first-class organic fertilizer for the garden. In the summer, it only needs to be dried in the sun after being removed from the sump
It is easiest to flush the inner walls and equipment with a high pressure washer. To do this dirty work manually is too laborious and time consuming. Yes, and not all sludge deposits can be quickly washed with a rag.
If the septic tank performs the functions of a conventional storage tank for sewage, then drains from it can only be pumped into the barrel of the sewer machine. It is forbidden to use them on a personal plot as fertilizer.
However, with a long break between cleanings, these sewages often turn into a viscous fecal mass, which is difficult to pump out. To liquefy it, a special chemistry based on nitrates, ammonium or formaldehyde will have to be poured into the container.
Rules for preparing an autonomous sewage system for winter:
Details of all the nuances of self-cleaning and maintenance of the septic tank "TOPAS":
How to get rid of sludge in the sump in the do-it-yourself way in the winter with your own hands without a call to the sewer:
There are no special difficulties in servicing septic tanks in the winter. Cleaning, preventive measures and sludge pumping are carried out according to technological schemes, which are also used in the summer. This process is quite dirty, like everything related to sewage.
Therefore, it is best to entrust it to the specialists of the slurry company. But you can do all the work yourself, if there is no fear of getting dirty in sewage.
Perhaps your opinion differs from what is stated in the article? Or do you have personal experience in the use and maintenance of septic tanks in the winter season? Please share it with visitors to our site. Leave comments in the block below.